NEC NDA-24305 Cell Phone User Manual


 
NDA-24305 CHAPTER 6
Page 177
Revision 1.0
DID ADDRESSING
STEP 1: Assign the Basic Data for ISDN (Refer to Chapter 3.)
STEP 2: ARTD - Assign the number of digits to be decoded in the System to the parameter DC (CDN=66)
of the Route of the B-channels and D-channel of a 24PRT which interfaces with the ISDN
line with DID addressing.
Note:
Specify “DC” on a route basis.
STEP 3: ACDD - Assign a Conversion Number for the Route of the B-channels in which the number of
decoding digits has been assigned with the ARTD command.
Assign “0” to the parameter “AD”.
If there are no attendant consoles in the system, set the DAY/NIGHT parameter to “N”
(Night Mode). The system functions as if in Night Mode.
Example of Office Data Assignment for DID Line (Digit Conversion)
CALLED PARTY
NUMBER
TERMINATING
STATION NO.
ARTD ACDD
REMARKS
DC DC CDC
438-3000 4000 4 3000 4000
See Example 1
438-3001 4001 4 3001 4001
438-3100 220 3 100 220
See Example 2
438-3101 221 3 101 221
438-3200 5150 4 3200 5150 See Example 3
CALLING PARTY
ISDN
4000/4001
DID NO. 438-3000/3001
PBX
<Example 1>
CALLING PARTY
ISDN
220/221
DID NO. 438-3100/3101
PBX
<Example 2>
CALLING PARTY
ISDN
5150
DID NO. 438-3200
PBX