NEC NDA-24305 Cell Phone User Manual


 
CHAPTER 3 NDA-24305
Page 14
Revision 1.0
BASIC DATA ASSIGNMENT FOR ISDN
(2) Condition: 24DTR is mounted in Slot 07 of PIM0 and 2DCH is mounted in Slot 05 of
PIM0, ACSC data is as follows.
Note 1:
The location of DCH (Dch Handler) must be assigned in the “CCH” parameter of this command.
Note 2:
Above is an example when #0 DCH of PA-2DCH circuit card is used.
STEP 6: ACIC1 - With respect to PC assigned in the ADPC command, assign CSCG of the Dch assigned in
the ACSC command.
STEP 7: ATRK - Assign the trunk data for Dch referring to Figure 3-1 and 3-2.
STEP 8: MBTK - Cancel Make Busy Status of all B channels in the PRT card.
Note:
Circuit card must be initialized after this assignment.
CSCG CCH CIC GROUP CSCG CCH CIC GROUP
130
(for Dch)
00002
00002
00002
00002
00002
00002
00002
00002
0
1
2
3
4
5
6
7
131
(for Bch)
00004
00004
00004
00004
00004
00004
00004
00004
0
1
2
3
4
5
6
7