NEC NDA-24305 Cell Phone User Manual


 
CHAPTER 6 NDA-24305
Page 206
Revision 1.0
SID TO NETWORK - PRESENT/SID TO NETWORK - PRIVACY
.
<For SID TO NETWORK-PRIVACY>
STEP 4: ASFC - Allow SID to Network-Privacy (SFI 94) to the SFC of the station.
SFI94=0/1=-/SID is not transfer to a destination.
Note:
This data is necessary for the temporary class to be converted by Authorization code.
STEP 5: Assign “Authorization Code” data.
When the originating PRT employs “Sub addressing” for the terminating call.
ACNP: OG/IC=O ACND: CNP=1
RT=10 SKIP=4
CNP=1 ADD=9
DC=032224111
Digits “032224111” are sent as SID.
PRT
Bch=RT10STA:2000
Pilot Number : 03-222-4111
ISDN
N
ote
1
When the originating PRT employs “DID-Addressing” for the terminating call.
ACNP: OG/IC=O ACND: CNP=2
RT=10 SKIP=0
CNP=2 ADD=5
DC=03222
Digits “03222 + DID No.” are sent as SID.
When the station that does not require the digit conversion (in the ACDD command) for a incoming call
originates a call to ISDN, the network will send a pilot number as SID.
511
PRT
Bch=RT10
Pilot Number : 03-222-4111
ISDN
Station for
DID-Addressing
Note 2