148 Chapter 5
C:\Spk\Ref\RefGuideRevE\CdmascrnE2.fm
CDMA Measurements - Screens and Control Fields
CDMA Measurements
Code Domain Complex Power
The Complex Power measurements provides two views of the current
Power values in the code domain:
• I Code View – IS-95 channels and IS-2000 channels combined
• Q Code View – IS-2000 channels only
Figure 5-15 Code Domain Complex Power
Screens on which this measurement is displayed
• CODE DOM (Code Domain Analyzer)
Code Domain Fast Power Synchronize
The Fast Power Synchronize measurement is designed to make a Power
measurement and ensure that all the internal values are set properly
for a Fast Power measurement. It will have the same look and feel as a
IS-2000 Code Domain Power measurement (see “Code Domain Power,
IS-2000” on page 146). After one fast power synchronize measurement
is made the Fast Power measurement can be made (see “Fast Power” on
page 147).
Screens on which this measurement is displayed
• Code Dom (Code Domain Analyzer, IS-2000)
I Code
Q Code
I Code shows combined IS-95 and IS-2000
Channel 0 is active in I Code, inactive in Q code. Means IS-95 only.