SYSTEM OPERATIONS
4. LINE LOAD CONTROL
In the PBX, Line Load Control can be activated automatically or manually as a countermeasure against abnor-
mal traffic congestion.
In the case of automatic control, the system automatically monitors an overloaded situation and restricts out-
going calls from stations and incoming calls from trunks.
In the case of manual control, the operator at an Attendant/Desk Console or the MAT restricts outgoing calls
from stations and incoming calls from trunks.
This section covers the following methods to activate Line Load Control:
Control by dialing an access code from the ATTCON/DESKCON
Control by entering command data from the MAT
System automatic monitoring
Operating Procedure
(1) Operations on the Attendant Console
By the operations on the ATTCON, restriction is effected on an outgoing call from a station having SFC
in which the SFI = 16 (Line Load Control) of ASFC command is set as RES=0 (incoming calls to that
station are allowed). For restricting incoming calls from a trunk, system data ASYD, SYS1, INDEX59,
b0=1 should be assigned.
Setting
Figure 6-6 Line Load Control Operations on ATTCONSetting
Press LOOP key.
Press CANCEL key.
Lamp (Figure 6-8) on control
panel lights.
System message [6-C] displays.
(SST)
Dial the access code for setting
Line Load Control.