NEC NDA-24300 Cell Phone User Manual


 
CHAPTER 8 NDA-24300
Page 532
Issue 1
CATK: Continuous Assignment of Trunk Data
CATK:
Continuous Assignment of Trunk Data
1. Functional Outline
This command can assign/delete many trunk data simultaneously which have consecutive numbers.
2. Parameters
Type/KIND
Note Note:
:Assign/Delete
Note:
Type
KIND
[When “Assign” is selected in the “Type/KIND” selection list box]
Input Data
RT: Route Number
TK (START): First Trunk Number [1-768]
TK (END): Last Trunk Number [1-768]
STEP: Trunk Count-up Step [1-10]
Note 1
LENS (START): First Line Equipment Number [6 digits]
LENS (END): Last Line Equipment Number [6 digits]
TN: Tenant Number
RSC: Route Restriction Class [0-15]
Note 2
SFC: Service Feature Class [0-15]
Note 2
GROUP (START): First Group Number [0-31]
GROUP (END): Last Group Number [0-31]
LEVEL (START): First Level Number [0-7]
LEVEL (END): Last Level Number [0-7]
TYPE: Count-up Type [1-6]
Note 3
1 = LEVEL GROUP UNIT
2 = LEVEL UNIT GROUP
3 = GROUP UNIT LEVEL
4 = GROUP LEVEL UNIT
5 = UNIT LEVEL GROUP
6 = UNIT GROUP LEVEL
Note 1:
In the parameter here, specify the size of increment between the consecutive trunk numbers to be as-
signed. See the example below:
Example: Input data Result
TK(START)=1
TK(END)=21
STEP=2
Note 2:
Data entry for this parameter is necessary when RT is 901 or 915.
Note 3:
TYPE parameter here determines how to arrange the trunk data. See [Details on Trunk Arrange-
ment “TYPE” ] (later pages) for details.
Trunk Number is assigned by 2 increments:
1357911...1921