CHAPTER 3 NDA-24300
Page 66
Issue 1
SYSTEM MESSAGES
This message displays when DLKC data transfer failure (temporary), shown in message [1-V], occurs more
than 16 times an hour. At this time, the faulty DLKC card is down and its switching network automatically
changes over.
➀
System status of faulty DLKC card
➁
Error Code
➂
Details on Switching Network
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b1 b0
Default Alarm:
MN
1-U
DLKC Data Transfer Failure (Permanent)
Default Grade:
3
Grade Modified: Lamp Modified:
b0: 0/1 = No. 0 system / No. 1 system
01H: Firmware fault
02H: Data transfer time out to DLKC
03H: No answer time out (at DLKC)
04H: Data parity error
b0: Status of Speech Path System (including DLKC)
0/1 = No. 0 system is ACT/No. 1 system is ACT
b1: Status of basic clock
0/1 = No. 0 system is ACT/No. 1 system is ACT