CHAPTER 6 NDA-24300
Page 452
Issue 1
SYSTEM OPERATIONS
11. ROUTINE DIAGNOSIS
For confirming its own servicing status, the system automatically executes self diagnosis every day, and dis-
plays the result of the diagnosis on a system message. By this function, possible causes for trouble can be dis-
covered in an early stage and possible trouble can be prevented from remaining undetected.
11.1 Related System Data
• ASYD, SYS1, INDEX86,
b0 – When routine diagnosis starts, and the result of the routine diagnosis is normal, the result
displays as system message [7-O].
0/1: Not displayed/To display
b1 – When the result of the routine diagnosis is abnormal, it displays as system message [7-P].
0/1: Not displayed/To display
b3, b2 – Processing at the time when Trunk Ineffective Hold is detected. Note
Note:
Trunk Ineffective Hold is a continuous state other than idle state within a predetermined duration while
routine diagnosis is in progress. Whether it is to be detected/not detected is assigned by ASYD, SYS1,
INDEX89.
• SYS1, INDEX87, 88 - Routine Diagnosis Start Time
Start time should be such a time at which the traffic of the office is the lowest.
To stop the routine diagnosis, set FF respectively to INDEX87, 88.
Bit
Except the trunks being held on two-way calls
(station-to-station call, station-to-trunk, trunk-
to-trunk call), the trunks being held at present
are forcibly released
All trunks being held at
present are forcibly
released
LENS of the trunk detected
display as system message
[7-P]
b3 b2
0
0
1
0
1
0
X
—
—
—
—
X
X
X
X
INDEX 87 0 2 (Hour) 2:00 a.m. is the start time.
INDEX 88 0 0 (Minute)