NEC NDA-24300 Cell Phone User Manual


 
NDA-24300 CHAPTER 8
Page 527
Issue 1
CADSD: Continuous Assignment of Station Data
CADSD:
Continuous Assignment of Station Data
1. Functional Outline
This command can assign/delete many station data simultaneously which have consecutive numbers.
2. Parameters
Input Data
Type: Assign/Delete
[When Assign is selected in the Type selection list box]
TN(START): Start Tenant Number
TN(END): End Tenant Number
STN(START): Start Station Number [Max. 6 digits]
Note 1
STN(END): End Station Number [Max. 6 digits]
Note 1
STEP: Station Count-up Step
Note 2
If using * and # [1-12]
If not using * and # [1-10]
LENS(START): First Line Equipment Number [6 digits]
LENS(END): Last Line Equipment Number [6 digits]
GROUP(START): First Group Number [0-31]
GROUP(END): Last Group Number [0-31]
LEVEL(START): First Level Number [0-7]
LEVEL(END): Last Level Number [0-7]
Note 1:
In the bottom part of the display, a check box is provided to determine whether to use "*" and "#" as
a part of the Station Number. If necessary, check the box.
Note 2:
In the parameter here, specify the size of increment between the consecutive station numbers to be
assigned. See the example below:
Example: Input data Result
STN(START)=100
STN(END)=200
STEP=10
Station Number is assigned by 10 increments:
When * and # are not used as part of STN
100 110 120 130 ... 190 200
When * and # are used as part of STN
10* 118 126 134 ... 1** 1#8