NDA-24300 CHAPTER 3
Page 45
Issue 1
SYSTEM MESSAGES
C-level infinite loop is a state where a clock-level program, running under clock interrupt disable state, is in
an infinite loop. This message displays when the counter value to check the normality of the processing has
become abnormal.
➀
Self-CPU Restart Information after
clock fault occurrence
➁
Mate-CPU Restart Information
➂
NMI Factor
Reference: See Chapter 5, Section 6.2, for the repair procedure.
0-E C-level Infinite Loop
1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
➀
➁ ➂ ➃ ➄ ➅ ➆
➇
4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX
➇
7: XXXX XXXX XXXX XXXX 8: XX00 0000 0000 0000 9: 0000 0000 0000 0000
➇
b7 b5 b4 b3 b0
b7 b5 b4 b3 b0
b7 b6 b5 b4 b3 b2 b1 b0
Default Alarm:
SUP
0-E
C-Level Infinite Loop
Default Grade:
2
Grade Modified: Lamp Modified:
b0: 0/1 = -/Monitor Restart
b3: 0/1 = -/Initialization
b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only)
b5: 0/1 = -/MBcontrol
b7: 0/1 = ACT/STBY (active system indication after restart)
b0: 0/1 = -/Monitor Restart
b3: 0/1 = -/Initialization
b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only)
b5: 0/1 = -/MBcontrol
b7: 0/1 = ACT/STBY (active system indication after restart)
b0: 0/1 = -/Reset by Power On
b1: 0/1 = -/Watchdog Timer timeout
b2: 0/1 = ISAGT is mounted/ISGAT is not mounted
b3: 0/1 = -/OSC clock interrupt on ISGAT
b4: 0/1 = -/IO parity Alarm
b5: 0/1 = -/IO ready Alarm
b6: 0/1 = -/External NMI