NEC NDA-24300 Cell Phone User Manual


 
CHAPTER 8 NDA-24300
Page 544
Issue 1
CMWL_T: Control Message Waiting Lamps Telephone Number
CMWL_T:
Control Message Waiting Lamps Telephone Number
1. Functional Outline
This command is used to control/display the Message Waiting Lamps ON/OFF status, by using Telephone
Numbers. When the station is a D
term
, this command can also be used to control the Message Waiting Lamp
Display. This command is available at NCN (for Fusion network) only.
2. Parameters
Input Data
TYPE: Designation by Telephone Number/Designation by LEN
UGN: User Group Number
Note 1
TELN: Telephone Number (max. 16 digits)
Note 1
LENS: Line Equipment Number
Note 2
MWLAMP: MW Lamp Status OFF/ON
MCI: Message Center MW Status OFF/ON
ATT: Attendant Console MW Status OFF/ON
STA: Station MW Status OFF/ON
VMM: Voice Mail Module MW Status OFF/ON
Note 1:
This parameter is valid when Type =1 is selected.
Note 2:
This parameter is valid when Type =2 is selected.
Display Data
FPC: Fusion Point Code (1-253)
Note 3
TN: Tenant Number
Note 3
STN: Physical Station Number (max. 5 digits for Business/max. 6 digits for Hotel system)
Note 3:
These parameters are for display only.
Buttons
Get: Click to get information on the MW status.
Set: Click to execute the assigned MW lamp control.
Exit: Click to exit this command.