![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/f/95/f951be8e-3276-4696-92fa-ccb64a2c46c9/f951be8e-3276-4696-92fa-ccb64a2c46c9-bg72.png)
4 - 49
No. 99MBC095A
4. SETTING UP THE MEASURING CONDITIONS
2. Where “Odd-numbered-edge cutting tool measurement function” has been set to
“Enable (
or )” in the Basic setup.
In this section only the setup operation is described. For the practical measurement
samples refer to Section 5.3.6 “Application of the odd-numbered-edge cutting tool mea-
surement”.
In this example assume that Number of samples =0, Calculation item = “Odd-numbered-
edge cutting tool measurement”, and Number of odd-numbered cutting edges = 3.
PROG
Step 1: The number of samples that has been already set
will be blinking.
PROG
Enter “0” as the number of samples.
PROG
Step 2: When
ENT
is entered, the setting will be
accepted and the operation will proceed to the
setting of workpiece automatic detection if the set
number of samples is “1”, and to the setting of
calculation items if the set number of samples is
“0”, or “2 to 999”.
PROG
Step 3: Select the calculation item. The following calcula-
tion items will be added to in the place of
“ , , , ”.
: Odd-numbered-edge cutting tool
diameter measurement
: Odd-numbered-edge cutting tool
run-out measurement
As each time is entered the displayed item will sequentially change as →
→ → → → , select .
PROG
Step 4: When
ENT
is entered, the setting will be
accepted. At this time the operation will enter the
setting of workpiece automatic detection if ,
, , , is selected
for the calculation item, or the setting of the
number of cutting edges of odd-numbered-edge
cutting tool if is selected for the
calculation item.
PROG
Enter “3” as the number of cutting edges of the
odd-numbered-edge cutting tool.
PROG
Step 5: When
ENT
is entered, the setting will be ac-
cepted, and the operation automatically proceeds
to the setting of workpiece automatic detection.
NOTE Where “ :Odd-numbered-edge cutting tool diameter measurement” or
“ :Odd-numbered-edge cutting tool run-out measurement” has been
selected for the calculation item, available segments will be automatically set and the
guidance ( ) for setting the segments will be displayed hereafter.