![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/f/95/f951be8e-3276-4696-92fa-ccb64a2c46c9/f951be8e-3276-4696-92fa-ccb64a2c46c9-bg79.png)
5 - 4
No. 99MBC095A
5.1.1.2 Setup that can be made directly from each setup item key
The user can enter the specific setup mode by pressing the corresponding setup item key in
the ready state.
1)
LIMIT
key
PROG
This key is used to enter the setup mode for only the
GO/NG judgment function.
If the
ENT
key is pressed after the setup data is
entered, the set up data will be saved in memory and
operation will return to the ready state. If the
LIMIT
key
or
SET
key is pressed halfway in the setup operation,
the setup operation is aborted, and operation returns to
the ready state.
2)
SHIFT
+
P.S V/
P.SET
key
PROG
Enters the setup mode only for presetting.
As soon as the setup data is saved in memory with the
procedure of “Entry of setup data” →
ENT
, the
presetting takes place and then the operation returns to
the stand-by state.If the
P.S V/
P.SET
key or
SET
key is
pressed halfway in the setup operation, the setup
operation is aborted, and operation returns to the ready
state.
3)
MASTER/REF
key
PROG
This key is used to enter the setup mode for only the
reference value and scale value.
If the
ENT
key is pressed after the setup data is entered,
the setup data will be saved and the operation will return
to the ready state. If the
REF
key or
SET
key is
pressed halfway in the setup operation, the setup opera-
tion is aborted, and operation returns to the ready state.
4)
SHIFT
+
MASTER/REF
key
PROG
This key combination is used to enter the setup mode
for only the mastering function.
If the
ENT
key is pressed after the setup data is
entered, the set up data will be saved in memory and
operation will return to the ready state. If the
MASTER/
OFFSET
key or
SET
key is pressed halfway in the
setup operation, the setup operation is aborted, and
operation returns to the ready state.