6. INTERFACE UNIT
,PR r
,PRT ttt
,SMP nnn
,(MAX,MIN,RNG,AVG)
,GN nn
,GLL±ddd.dddd
,GLH±ddd.dddd
,(GMX,GMN,GAG,GRG)
Data output conditions
Periodic data output conditions
Periodic output timer
Number of sample measurements
Setting the statistical item for sample measurement
(Maximum value, minimum value, range, mean)
Group sizes subject to judgment *2
Lower tolerance limit for group judgment
Upper tolerance limit for group judgment
Statistical item for group judgment
(Maximum value, minimum value, mean, range)
OK 0RSV000000
Item
Reception command
Response command
(DATA FORMAT)R
CR
CL
D
ST
NST
(DATA FORMAT) *4
OK
(DATA FORMAT)
OK
OK
OK
OK
Start of single-run measurement
Continuous-run
measurement
Request of measurement data
R
STOP
No response command
(DATA FORMAT)
Zero-run measurement
Measurement start
command
Measurement stop
command
Measurement start
command
Measurement stop
command
Statistical processing
calculation
Performs statistical
processing
Does not perform
statistical processing
Current program only
All programs
Erasing the statistical
processing memory
MC
MCAL
OK
Request of statistical processing results
STAT (STAT FORMAT)
GP-IB *5
Output to printer.
Perform service request.
Do not perform service request.
Condition setting of automatic workpiece detection *2
Number of measurement times
Invalidation period
Lower detection limit
Upper detection limit
PR
SRQ
NSRQ
Request of conditions list for automatic workpiece
detection
RA (RA FORMAT)
I/O timing signal
*1: If "Performing the ultra-fine wire measurement" is specified in the basic setup (also on the LSM-500H), designating this command
*1: results in ER-6.
*1: Do not use the SHL command unnecessarily unless there is a need, since it adversely affects the measuring accuracy.
*1: In order to restore the standard threshold voltage, enter the following command:
*1: "SHL50" Resets to 50%, which is the standard.
*1: "STR" Records the value in memory.
*2: Designating any command of the functions which are set to "Not used" in the basic setup will result in ER6.
*3: If "Copying the target value to the reference value" is specified in the basic setup, designating this command results in ER6.
*4: Responds with measurements according to the data output conditions.
*5: Results in ER6 on the RS-232C.
ER7
GP-IB SRQ status byte
0RSV010NGGO1
0RSV010NGGO1
0RSV000000
0RSV010001
0RSV000000
0RSV010NGGO1
0RSV000000
0RSV000001
Automatic workpiece detection control *2
AUT, S OK 0RSV000000
0RSV000000
0RSV000000
AUT
,N mmm
,D tttt
,L±ddd.dddd
,H±ddd.dddd
OK 0RSV000000
0RSV000001
0RSV001111
*2