Agilent Technologies E6380-90073 Cell Phone Accessories User Manual


 
Chapter 1 129
GPIB Command Dictionary
CDANalyzer subsystem
:SCALe:PHASe <string>
:SCALe:PHASe?
These commands set/query the scale that is used when measuring code
domain phase when using the code domain analyzer.
Syntax
CDAN:SCAL:PHAS ‘1 mRad’
‘2 mRad’
‘5 mRad’
‘10 mRad’
‘20 mRad’
‘50 mRad’
CDAN:SCAL:PHAS?
Screen/field equivalent
CDAN:SCAL:PHAS controls the Phase/div field on the Phase
measurement menu of the CODE DOM screen when the CDMA
standard is set to “IS-95 Only”.
:SCALe:POWer <string>
:SCALe:POWer?
These commands set/query the scale that is used when measuring code
domain power when using the code domain analyzer.
Syntax
CDAN:SCAL:POW ‘1 dB/div’
‘2 dB/div’
‘5 dB/div’
CDAN:SCAL:POW?
Screen/field equivalent
CDAN:SCAL:POW controls lower subfield of the Pwr Scale field on the
Marker menu of the CODE DOM screen when the CDMA standard is
set to “IS-95 Only”. This field is displayed only when a power or fast
power measurement is selected.