Chapter 1 143
GPIB Command Dictionary
CDANalyzer subsystem
:IS2000:TRIGger:ARM
IS-2000 only. This command arms code domain measurements. This
command does not affect continuous measurement and will always be
overridden by GPIB triggering commands. To effectively put the code
domain analyzer in single triggering mode, use the
TRIG:MODE:RETR SING command. For continuous triggering, use
TRIG:MODE:RETR REP. See “TRIGger subsystem” on page 346 for a
more complete discussion of GPIB triggering.
Syntax
CDAN:IS2000:TRIG:ARM !arms the measurement
Screen/field equivalent
CDAN:IS2000:TRIG:ARM controls the Arm Meas subfield of the
Analyzer field on the Main menu of the CODE DOMAIN screen when
the CDMA standard is set to “IS-2000”.
:IS2000:TRIGger:DARM
IS-2000 only. This command disarms the code domain measurements.
This command does not affect continuous measurement and will always
be overridden by GPIB triggering commands. To effectively put the code
domain analyzer in single triggering mode, use the
TRIG:MODE:RETR SING command. For continuous triggering, use
TRIG:MODE:RETR REP. See “TRIGger subsystem” on page 346 for a
more complete discussion of GPIB triggering.
Syntax
CDAN:IS2000:TRIG:DARM !disarms measurements that have been
previously armed
Screen/field equivalent
CDAN:IS2000:TRIG:DARM controls the Disarm subfield of the
Analyzer field on the Main menu of the CODE DOMAIN screen when
the CDMA standard is set to “IS-2000”.