Agilent Technologies E6380-90073 Cell Phone Accessories User Manual


 
Chapter 1 65
GPIB Command Dictionary
AFG1|AFGENERATOR1 subsystem
:FM <real number>
:FM?
This command sets FM modulation deviation when the AFG1:DEST
‘FM’ command is used.
This command utilizes the “Real Number Setting Syntax” on page 299.
Syntax
AFG1:FM <real number>
AFG1:FM?
Screen/field equivalent
AFG1:FM controls the AFGen1 To field (lower subfield) on the RF
GENERATOR screen.
:FREQuency <real number>
:FREQuency?
This command set the frequency of audio frequency generator 1.
This command utilizes the “Real Number Setting Syntax” on page 299,
not including the :STATe command.
Syntax
AFG1:FREQ <real number>
AFG1:FREQ?
Screen/field equivalent
AFG1:FREQ controls the AFGen1 Freq field on the RF GENERATOR
screen.