Agilent Technologies E6380-90073 Cell Phone Accessories User Manual


 
Chapter 1 165
GPIB Command Dictionary
CONFigure subsystem
:SPOR9|SPORT9|SB9|SP9:BAUD <string>
:SPOR9|SPORT9|SB9|SP9:BAUD?
These commands set/query the baud rate of the SERIAL 9 port.
Syntax
CONF:SPOR9:BAUD ‘150’
‘300’
‘600‘
‘1200‘
‘2400‘
‘4800‘
‘9600‘
‘19200‘
CONF:SPOR9:BAUD?
Screen/field equivalent
CONF:SPOR9:BAUD controls the Serial Baud field of the I/O
CONFIGURE screen.
:SPOR9|SPORT9|SB9|SP9:PARity <string>
:SPOR9|SPORT9|SB9|SP9:PARity?
These commands set/query the parity of the SERIAL 9 port.
Syntax
CONF:SPOR9:PAR‘None’
‘Odd’
‘Even’
‘Always 1’
‘Always 0’
CONF:SPOR9:PAR?
Screen/field equivalent
CONF:SPOR9:PAR controls the Parity field of the I/O CONFIGURE
screen.