Agilent Technologies E6380-90073 Cell Phone Accessories User Manual


 
Chapter 1 59
GPIB Command Dictionary
AFANalyzer subsystem
:GTIMe <real number>
:GTIMe?
This command sets the gate time (how long the AF counter samples the
input signal) for the audio frequency counter.
This command utilizes the “Real Number Setting Syntax” on page 299,
but does not use the :STATe command.
Syntax
AFAN:GTIM <real number> !valid from 10 milliseconds to 1
second
AFAN:GTIM?
Screen/field equivalent
AFAN:GTIM controls the AF Cnt Gate field on the AF ANALYZER
screen.
:INPut <string>
:INPut?
These commands set/query the input to the audio analyzer.
Syntax
AFAN:INP ‘FM Demod’
‘AM Demod’
‘SSB Demod’
‘Audio In’
‘Ext Mod’
‘FM Mod’
‘AM Mod’
‘Audio Out’
AFAN:INP?
Screen/field equivalent
AFAN:INP controls the AF Anl In field on the AF ANALYZER screen.