Agilent Technologies E6380-90073 Cell Phone Accessories User Manual


 
234 Chapter 1
GPIB Command Dictionary
MEASure subsystem
:CDANalyzer:IS2000:ADC <meas cmds>
:CDANalyzer:IS2000:ADC?
IS-2000 only. These commands set/query the ADC measurement in the
Code Domain analyzer.
This measurement utilizes the Number Measurement Syntax, but does
not use the :METer command.
Syntax
MEAS:CDAN:IS2000:ADC <meas cmds>
!See “Number Measurement Syntax” on page 283.
MEAS:CDAN:IS2000:ADC?
Screen/field equivalent
MEAS:CDAN:IS2000:ADC? reads the ADCfs measurement field on the
Gain menu of the CODE DOMAIN screen when the CDMA standard is
set to “IS-2000”.
:CDANalyzer:IS2000:CARRier[:FEEDthrough]?
IS-2000 only. This query returns a floating point number representing
the carrier feedthrough currently displayed in the Code Domain
analyzer of the Test Set.
Syntax
MEAS:CDAN:IS2000:CARR[:FEED]?
Screen/field equivalent
MEAS:CDAN:IS2000:CARR[:FEED]? reads the Carrier FT
measurement field on the CODE DOMAIN screen when the CDMA
standard is set to “IS-2000”.