Agilent Technologies E6380-90073 Cell Phone Accessories User Manual


 
Chapter 1 237
GPIB Command Dictionary
MEASure subsystem
:CDANalyzer:IS2000:MARKer:CHANnel:RATE:RC5?
IS-2000 only. This query returns the RC-5 data rate value for the
channel selected by the Marker’s current position. The return value is
an integer.
Syntax
MEAS:CDAN:IS2000:MARK:CHAN:RATE:RC5?
Screen/field equivalent
MEAS:CDAN:IS2000:MARK:CHAN:RATE:RC5? reads the RATE RC-5
field of the CODE DOMAIN screen when the CDMA standard is set to
“IS-2000” and Sprd Fact is selected.
:CDANalyzer:IS2000:MARKer:CHANnel:SPRead[:RATE]?
IS-2000 only. This query returns the spread factor (1, 2, 4, 8, 16, 32, 64,
128) of the channel selected by the Marker’s current position. The
return value is an integer.
Syntax
MEAS:CDAN:IS2000:MARK:CHAN:SPR[:RATE]?
Screen/field equivalent
MEAS:CDAN:IS2000:MARK:CHAN:SPR:RATE? reads the SPRD FACT
field of the CODE DOMAIN screen when the CDMA standard is set to
“IS-2000”.
:CDANalyzer:IS2000:MARKer:CHANnel[:WALSh]:ORDer?
IS-2000 only. This query returns the Walsh order (1, 2, 3, 4, 5, 6, 7) of
the channel selected by the marker’s current position.
Syntax
MEAS:CDAN:IS2000:MARK:CHAN:WALS:ORD?
Screen/field equivalent
MEAS:CDAN:IS2000:MARK:CHAN:WALS:ORD? reads the Walsh Ord
field of the CODE DOMAIN screen when the CDMA standard is set to
“IS-2000”.