Agilent Technologies E6380-90073 Cell Phone Accessories User Manual


 
Chapter 1 205
GPIB Command Dictionary
DISPlay subsystem
DISPlay subsystem
The DISPlay subsystem controls the display of screens. A screen should
be displayed before a measurement from that screen is made.
DISPlay
DISPlay?
DISP sets/queries which screen is displayed. You use the DISP REM
command to lock the Test Set’s display.
Syntax
DISP AFANalyzer !AF ANALYZER screen
DISP CANanalyzer !CDMA ANALYZER screen
DISP CDANalyzer !CODE DOM screen (code domain analyzer)
DISP CONFigure !INSTRUMENT CONFIGURE screen
DISP DECoder !SIGNALING DECODER screen
DISP ENCoder !SIGNALING ENCODER screen
DISP HELP !HELP screen
DISP IOConfigure !I/O CONFIGURE screen
DISP IQPlot !IQ PLOT screen
DISP MESSages !MESSAGES screen
DISP OSCilloscope !SCOPE screen
DISP PCONfigure !PRINTER CONFIGURE screen
DISP RFANalyzer !RF ANALYZER screen
DISP RFGen !RF GENERATOR screen
DISP SANalyzer !SPEC ANL screen
DISP SERVice !SERVICE screen
DISP TCONfigure !TESTS (External Devices) screen
DISP REMote !locks the display
DISP? !returns the screen name being displayed