Agilent Technologies E6380-90073 Cell Phone Accessories User Manual


 
266 Chapter 1
GPIB Command Dictionary
MEASure subsystem
:DEC:NAMPs|NTACs:RECC:DATA?
This command reads the decoded RECC data, serially, as it received.
Syntax
MEAS:DEC:NAMP:RECC:DATA? !returns a quoted string
Screen/field equivalent
MEAS:DEC:NAMP:CDAT? reads the RECC Data (hex) measurement
field on the SIGNALING DECODER screen when the Mode field is set
to NAMP-NTAC , the Measure field is set to Data and the Channel field is
set to Cntl.
:DEC:NAMPs|NTACs:RVC:DATA?
This command reads the decoded RVC data, serially, as it is received.
Syntax
MEAS:DEC:NAMP:RVC:DATA? !returns a quoted string
Screen/field equivalent
MEAS:DEC:NAMP:RVC:DATA? reads the RVC Data (hex)
measurement field on the SIGNALING DECODER screen when the
Mode field is set to NAMP-NTAC, the Measure field is set to Data and the
Channel field is set to Voice.
:DEC:NAMPs|NTACs:DSAT:DATA?
This command reads the decoded DSAT/DST data, serially, as it is
received.
Syntax
MEAS:DEC:NAMP:DSAT:DATA? !returns a quoted string
Screen/field equivalent
MEAS:DEC:NAMP:DSAT:DATA? reads the DSAT/DST (hex)
measurement field on the SIGNALING DECODER screen when the
Mode field is set to NAMP-NTAC, the Measure field is set to DSAT and the
Channel field is set to Voice.