Chapter 1 231
GPIB Command Dictionary
MEASure subsystem
:CDANalyzer:MARKer:TIME <meas cmnd>
:CDANalyzer:MARKer:TIME?
IS-95 Only mode. These commands set/query the time at the marker on
the code domain analyze’s trace during a timing measurement (see
CDAN:MEAS on page 124). This measurement is made relative to the
value at Walsh Code 0.
This measurement utilizes the Number Measurement Syntax, but does
not use the :METer command.
Syntax
MEAS:CDAN:MARK:TIME <meas cmd>
!See “Number Measurement Syntax” on page 283.
MEAS:CDAN:MARK:TIME?
Example
MEAS:CDAN:MARK:TIME?
Screen/field equivalent
MEAS:CDAN:MARK:TIME? reads the Time field on the Marker menu
of the CODE DOM screen when a timing measurement is selected. This
applies when the CDMA standard is set to “IS-95 Only”.
:CDANalyzer:PNOFfset?
IS-95 Only mode. This command queries the PN offset measurement.
Syntax
MEAS:CDAN:PNOF?
Example
MEAS:CDAN:PNOF?
Screen/field equivalent
MEAS:CDAN:PNOF? queries the PN Ofs measurement field on the
CODE DOM screen whent he CDMA standard is set to “IS-95 Only”,
and the CD pwr unit is set to Abs on the CD Setup image of the CODE
DOMAIN screen.