Agilent Technologies E6380-90073 Cell Phone Accessories User Manual


 
Chapter 1 135
GPIB Command Dictionary
CDANalyzer subsystem
:IS2000:MARKer:POSition <integer>
:IS2000:MARKer:POSition?
IS-2000 only. These commands set/query the integer that corresponds
to the current position of the marker in the CODE DOMAIN screen
when the CDMA standard is set to “IS-2000”.
Syntax
CDAN:IS2000:MARK:POS <integer> !values from 0 to 127
CDAN:IS2000:MARK:POS?
Screen/field equivalent
CDAN:IS2000:MARK:POS controls the Marker Pos field of the Marker
image of the CODE DOMAIN screen when the CDMA standard is set to
“IS-2000”.
:IS2000:MARKer:REFerence <string>
:IS2000:MARKer:REFerence?
IS-2000 only. These commands set/query the power reference, as a
string, in terms of dB, for the code domain analyzer.
Syntax
CDAN:IS2000:MARK:REF <string>
CDAN:IS2000:MARK:REF?
Screen/field equivalent
CDAN:IS2000:MARK:REF controls the Pwr Ref field on the Marker
image of the CODE DOMAIN screen when the CDMA standard is set to
“IS-2000”.