Agilent Technologies E6380-90073 Cell Phone Accessories User Manual


 
310 Chapter 1
GPIB Command Dictionary
RFGenerator subsystem
:FREQuency <real number>
:FREQuency?
These commands set/query the frequency of the RF generator. The Test
Set must first be in frequency tuning mode. (See CONF:RFD ‘Freq’ on
page 164).
This command utilizes the “Real Number Setting Syntax” on page 299,
but does not use the :STATe command.
Syntax
RFG:FREQ <real number>
RFG:FREQ?
Screen/field equivalent
RFG:FREQ controls the RF Gen Freq field on the RF GENERATOR
screen, when in frequency tuning mode. This field is also displayed on
the spectrum analyzer’s RF Gen menu.
:MODulation:AOUT <string>
:MODulation:AOUT?
These commands set/query the coupling between the demodulated
audio and the AUDIO OUT port.
Syntax
RFG:MOD:AOUT ‘AC’
‘DC’
RFG:MOD:AOUT?
Screen/field equivalent
RFG:MOD:AOUT controls the Audio Out field on the RF GENERATOR
screen.