Agilent Technologies E6380-90073 Cell Phone Accessories User Manual


 
254 Chapter 1
GPIB Command Dictionary
MEASure subsystem
:CDANalyzer:IS2000:TRACe:POWer:COMPlex:I:ALL?
:CDANalyzer:IS2000:TRACe:POWer:COMPlex:COMBined:ALL?
:CDANalyzer:IS2000:TRACe:POWer:COMPlex:Q:ALL?
:CDANalyzer:IS2000:TRACe:POWer:COMPlex:IS2000:ALL?
IS-2000 only. These queries return the information necessary to
recreate the Code Domain trace when making a Complex Power
measurement. The returned entity consists of 128 four-value records for
each bar in the trace. The four values for each record are channel
number, I value for this channel, Q value for this channel and a flag
indicating that the next bar should be connected to this bar as part of a
wider supplemental channel.
If the selected location is part of a supplemental channel, all the Walsh
channels that comprise the supplemental channel will be returned.
Syntax
MEAS:CDAN:IS2000:TRAC:POW:COMP:I:ALL?
MEAS:CDAN:IS2000:TRAC:POW:COMP:COMB:ALL?
MEAS:CDAN:IS2000:TRAC:POW:COMP:Q:ALL?
MEAS:CDAN:IS2000:TRAC:POW:COMP:IS2000:ALL?
Screen/field equivalent
There are no fields on the CODE DOMAIN screen equivalent to the
return values for these queries. These values are only accessible when
the CDMA standard is set to “IS-2000”, the measurement selected is
Complex Power, and CD pwr unit is set to Rel on the Reference image
of the CODE DOMAIN screen.