Chapter 12 Serial Interface 3
Operation
XII - 32
Figure 12-3-16 Master Transmission Timing
Master Transmission Timing
SDA
SCL
Interrupt
12
. .
. .
8 ACK 1 2 8
IICBSY
Set data to SC3TRB
Clear IICBSY flag
(1)
(2) (3)
(4) (5)
(6)
Set data to SC3TRB
ACK
8-bit
transmission
8-bit
transmission
(1) Output start condition.
(2) Bus released period, ACK bit is received.
(3) Interrupt transaction.
- Disable start condition : SC3STE = 1 →0
- Start communication : set data to SC3TRB
(4) Receive ACK bit.
(5) Interrupt transaction.
- Finish communication : clear the IICBSY flag.
(6) Generates stop condition.