Agilent Technologies 8922M Cell Phone User Manual


 
4-27
Screens
Cell Control - Active Cell
Cell Control - Active Cell
This screens allows you to set up a call with the mobile to be tested and gives you
access to the measurement screens.
1. Active Cell
TestMode
CW Generator
This field selects the operating mode of the Agilent 8922M/S. The modes are:
Active Cell - this mode allows a call between the mobile phone and the
Agilent 8922M/S.
Test Mode - this mode sets the Agilent 8922M/S to work with a mobile phone
running a test mode. This mode allows you to transmit either BCCH only or
BCCH and TCH and measures an independent GSM signal.
CW Generator - this mode sets the Agilent 8922M/S as a signal generator.
2. Amplitude
(Base Station)
This field selects what amplitude the Agilent 8922M/S should be transmitting.
See Also Screens: RF Generator/RF Analyzer (RF Generator)
3. Audio This field displays the audio measurements screen.