Agilent Technologies 8922M Cell Phone User Manual


 
4-83
Screens
Output RF Spectrum, Main View (Option 006 Only)
4. Mode This field selects the Output RF Spectrum measurement Mode.
Choices Ramping measures the Output RF Spectrum power due to
ramping. (The peak value is returned within the time interval 28 µs
before bit 0 to 28 µs after bit 147 or bit 87, depending on the burst
type.)
Ramp Ref makes a reference measurement needed for the Output
RF Spectrum measurement when making ramping measurements.
Modulatn (modulation) measures the Output RF Spectrum power
due to modulation.
Mod Ref makes a reference measurement needed for the Output
RF Spectrum measurement when making modulation
measurements.
5. Output RF
Spectrum
This field displays the measured Output RF Spectrum power at the specified Freq
Offset setting.
See Also Keys: ON/OFF, HI LIMIT, LO LIMIT, REF SET, AVG, Units
6. Single/Cont Single allows one test to be performed. Cont allows testing to automatically repeat.
7. Trig Delay This field sets the time delay between a valid trigger event and the beginning of a
measurement.
Range 0 to 5000.00 µs
8. View This field selects the alternate views of the Output RF Spectrum measurement.
Choices Main displays the Output RF spectrum display as a text screen.
Trace displays Output RF Spectrum power spectral density (at the
Freq Offset setting) versus time.