Agilent Technologies 8922M Cell Phone User Manual


 
2-4
Making Measurements
Agilent Technologies 8922M/S Operating Modes
To configure the Agilent 8922M/S to the desired operating mode, carry out the
following instructions, referring to Figure 2-1 on page 4 for the position of the
fields.
Ensure (1) is set to mobile phone type you require (GSM900, E-GSM, DCS1800,
or PCS1900).
NOTE For use with DCS1800 or PCS1900, refer to the HP/Agilent 83220A/E Users Guide
which explains how to configure the Agilent 8922M/S to test other mobile phone
formats.
Use the knob to move the cursor to the lower field below the Operating Mode (2).
Push the knob and select the desired Operating Mode (ACTIVE CELL, TEST
MODE, or CW GENERATOR) from the menu which appears at the bottom
right-hand side of the screen.
Figure 2-1 Agilent 8922M/S Operating Modes
In addition to the three main operating modes, there are three other modes available.
These are:
ACTIVE CELL+
TEST MODE+
CW GENERATOR+
These “+” modes have all the features of the other modes but include extra
diagnostic information on the screen. This information is designed to help advanced
users in fault-finding mobile phones.
1
2