Agilent Technologies 8922M Cell Phone User Manual


 
3-14
Verifying Performance
Agilent Technologies 8922M/S Specifications
Agilent Technologies 8922M/S Specifications
NOTE: If you have the Agilent 8922M/S Option 010 Multi-Band Test System, refer to the
appropriate Agilent 8922 Multi-Band User’s Guide for more information on
specifications relevant to dual band testing.
GSM900 and
E-GSM900
Functionality
RF Generator
Specifications
Frequency
Bit/Frame Error Rate Measurements: Class 1a, 1b, and Class II bits in both raw and residual form.
Also Burst-by-Burst Bit Error Measurement
MS Power Output Level Control: 0 to 19 with RF analyzer auto adjust
Broadcast Channel Capability: BCCH + CCCH or BCCH + CCCH + SDCCH/4
Control Channels (SDCCH, FACCH,
SACCH)
BCCH + CCCH, BCCH + CCCH + SDCCH/4, SDCCH/8
(non-hopped), SACCH/FACCH
Call Control Capabilities BS originated call (FS/EFS), MS originated call (FS/EFS),
MS camp on, BS call disconnect, MS call disconnect
Traffic Channels TCH (FS/EFS)
HSCSD 2x1 and 2x2, 9.6 kbs and 14.4 kbs
Timing Auto, manual, uplink-downlink, offset measurement
Hopping Two independent, user definable MA tables with offsets
Speech Encoding/Decoding Full rate speech
Speech Echo Mode User selectable delay 0 to 5 sec on Agilent 8922M, fixed
delay on Agilent 8922S
Measurement Coordination Flexible control of burst type, ARFCN, and timeslot.
SACCH MEAS Result RXLEV, RXQUAL, and timing advance.
SMS Cell Broadcast Two predefined messages with user definable attributes
(code, update number, language and identifier).
Range 10 MHz to 1 GHz
Resolution 1 Hz
Accuracy
Reference accuracy
± 0.5 Hz
Stability Same as reference