Agilent Technologies 8922M Cell Phone User Manual


 
4-57
Screens
Fast Bit Error
5. Intermediate
Results
This field displays the number of bits that have been tested during a measurement
that is currently running. This number includes only bits that are tested by the
selected measurement type.
6. Measure Bit Type Displays the fixed type of bit error test result.
7. Mobile Reports The mobile reports reflect the status of the signal the mobile is receiving. These are:
RX Qual
RX Lev
8. Mobile When Compatibility Switch mode is being used (refer to Chapter 3, Using
Compatibility Switch), Chan, TX Lev and Timeslot fields under Mobile are
replaced with the To Screens List (see item Field Types, (5) at the start of this
chapter).
9. Mode This field sets which screen will be displayed once the Bit Error measurements has
been selected from the Cell Control screen.
Choices STD means the screen will display the standard Bit Error Screen.
FAST means the screen will display the Fast Bit Error Screen, as
shown above.