Panasonic 700 Cell Phone User Manual


 
Section 700 - Operation Chapter 3. System Features
ICX-50-700 ICX (International) issued October 2000 49
576-port system:1 to 72 MCO tenant groups
Hardware Requirements
•N/A
Considerations
When you first assign a trunk to Trunk Tenant Group from the initial setting of (0), the system
automatically assigns the trunks as a member of the same number MCO Trunk Group (FF5-2 and
FF5-3). For instance, if Trunk 10 is assigned as a member of Trunk Tenant Group 1, then Trunk
10 is automatically assigned as a member of MCO Outbound Trunk Group 1 and MCO Inbound
Trunk Group 1. These assignments can be manually changed if desired.
Memory Backup
Description
Data stored in the CPC card can be copied to another CPC card in the OP2 card slot for the first CCU.
This is particularly useful when performed after completion of initial system setup (as a recovery
measure) or before major changes are made to system configuration. This backup CPC can then be
used to immediately restore system operation.
This feature is a maintenance feature to be performed by the System certified dealer only.
Hardware Requirements
A second CPC card that matches the type installed must be used to copy the memory.
Considerations
•N/A
Music-on-Hold
Description
The System can provide Music-on-Hold (MOH) to parties on hold (either trunk, extension, or
network party). The MOH feature can also be used to play announcements or advertisements if
desired.
Hardware Requirements
The music source must be purchased separately. It is not provided with the System.