Panasonic 700 Cell Phone User Manual


 
58 ICX (International) issued October 2000 ICX-50-700
Chapter 3. System Features Section 700 - Operation
Network Transfer Recall
Version 3.5 and later
Network Transfer Recall allows a call which has been transferred to another node to recall back to the
transferring extension.
Tandem Connection
Tandem Connection allows calls that are received over the network tie lines to be automatically routed
on to another PBX or out to the public network.
Hardware Requirements
T1 (USA), E&M (HK) or AC-15 (UK) Card
Considerations
•N/A
Non-Blocking Architecture
Description
The System is totally non-blocking. All extension and outside lines are available for use at the same
time.
Hardware Requirements
The CPC-96 supports up to 96 ports. The CP-288 supports up to 288 ports and should be
combined with time switch card TSW288. The CPC-576 supports up to 576 ports and should be
combined with time switch card TSW576.
Considerations
•N/A
Power Failure Transfer
Description
Power Failure Transfer provides telephone service to a limited number of Single Line Telephones
(SLTs) during a power failure. The SLTs are connected to the trunk via a Power Failure Unit (PFU). In
the event of a power failure, the power failure extensions have dial tone directly from the trunk.
(System features and restrictions do not apply.)
Hardware Requirements
Power Failure Unit (VB-43703)
An SLT that will be connected to the PFU.