Panasonic 700 Cell Phone User Manual


 
84 ICX (International) issued October 2000 ICX-50-700
Chapter 4. User Maintenance Section 700 - Operation
Hardware Requirements
•N/A
Considerations
•N/A
Set Caller ID Logging Extensions
Description
You can assign Caller ID Call Logging to extensions. The system is limited to 20 call logging
extensions per cabinet as follows:
6. Dial the extension number.
7. Press the HOLD key. Enter CODE displays
8. Enter the destination extension.
9. Press the HOLD key to store the entry. Next extension number displays
10. To set Call Forward No Answer destinations for additional
extensions, press the volume up and down key or press the
HOLD key to move to the desired Extension.
11. Repeat steps 9-11 until all extension are entered.
12. Press the
MEMORY key to exit the entry mode.
13. To return to the top menu level (81), press the PROG key.
OR...
To exit the User Maintenance mode, press the ON/OFF
key.
81-
User MAINT displays
OR...
ON/OFF LED goes off
Number of Cabinets
Total Number of
Call Log Extensions
1
20
2
40
3
60
4
80
5
100
6
120
Action Result