![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/f/fa/ffa63819-0092-4e25-b43b-b3dd7442913c/ffa63819-0092-4e25-b43b-b3dd7442913c-bg84.png)
xStack
®
DGS-3400 Series Layer 2 Gigabit Managed Switch CLI Manual
128
DGS–3426:5#config double_vlan Tiberius delete 1:4–1:8
Command: config double_vlan Tiberius delete 1:4–1:8
Success.
DGS–3426:5#
show double_vlan
Purpose Used to display the Q-in-Q VLAN settings on the Switch.
Syntax
show double_vlan {<vlan_name>}
Description This command is used to display the current Q-in-Q VLAN parameters configured on the
Switch.
Parameters vlan name – Enter the name of a previously created VLAN for which to display the
settings.
Restrictions None.
Example usage:
To display parameters for the Q-in-Q VLAN “Tiberius”:
DGS–3426:5#show double_vlan Tiberius
Command: show double_vlan Tiberius
Global Double VLAN : Enabled
====================================================
SPVID : 6
VLAN Name : Tiberius
TPID : 0x9200
Uplink ports :
Access ports : 1:4–1:8
Unknow ports :
––––––––––––––––––––––––––––––––––––––––––––––––––––
Total Entries : 1
DGS–3426:5#
enable pvid auto_assign
Purpose Used to enable auto–assign PVID.
Syntax
enable pvid auto_assign
Description This command is used to enable auto–assign PVID.
If “PVID auto_assign” is disabled, PVID can only be changed by PVID configuration (user
changes explicitly). The VLAN configuration has no effect on PVID.
If “PVID auto_assign” is enabled, PVID will be possibly changed by PVID or VLAN
configuration. When a user configures a port to VLAN X’s untagged membership, this
port’s PVID will be updated with VLAN X. In the form of VLAN list command, PVID is
updated with the last item of VLAN list. When user removes a port from the untagged
membership of the PVID’s VLAN, the port’s PVID will be assigned with “default VLAN”.
The default setting is enabled.
Parameters None.
Restrictions Only Administrator and Operator-level users can issue this command.
Example usage:
To enable the auto–assign PVID: