Polycom RealPresence Resource Manager System Operations Guide Troubleshooting Specific Types of Issues
594 Polycom, Inc.
Point-to-Point Calling Problems and Solutions
MCU and Gateway Dialing Problems and Solutions
Problem Description Solutions
A call with an alias as the
dial string from a registered
endpoint cannot be placed
to another registered
endpoint. The two
endpoints are in different
sites.
The site link between the sites
in which the endpoints reside is
not correctly defined or is
missing.
No bandwidth is available to
the site link.
The calling bit rate is higher
than the bit rate defined in the
site link.
ISDN alternate routing is not
available.
Dialing rules may not be
enabled or may be set to block
instead of route.
Go to Admin > Topology > Site Links
and make sure that a site link exists
between the two networks.
Make sure that the IP addresses of
both endpoints are included in their
respective sites.
If site topology is defined for both
endpoints, verify that there is enough
bandwidth in the site links between
the two sites.
Verify that the dialing bit rate is lower
or equal to that of the maximum bit
rate defined for the site links.
If the endpoint is ISDN capable, verify
that the ISDN parameter is correct.
Problem Description Solutions
Call fails when using an
MCU service.
Dialing an MCU service
results in a network error.
The call using the MCU service is
rejected because of one of the
following:
The MCU is not registered.
The MCU is offline.
The MCU prefix is not
registered as an E.164 alias.
The MCU resource issue was
sent through resource
allocation indication or
resource allocation.
Verify that the MCU is registered.
Verify that the MCU is online. If the
device is offline, reboot it.