Set the internal clock to On when you are connecting to a device or system that does not
provide a clock source. Otherwise, set the internal clock to Off.
4. If you turned the internal clock on, enter a value in the Internal clock speed text box.
If the device can generate only certain line rates, and the configured line rate is not one of
these values, the device selects the next highest available line rate.
5. Click Full Duplex or Loopback in the Channel Mode field.
Full duplex is the normal mode of operation.
6. Click Frame relay in the Encapsulation field.
Click Apply.
7. Enter a number in the Keepalive text box to configure the frame relay keepalive interval.
Click Apply.
This value sets the interval, in seconds, between keepalive protocol message transmissions.
These messages are used periodically to test for an active remote system.
Note
This value must be identical to the keepalive value configured on the system at the other
end of a point-to-point link, or the link state fluctuates.
8. Click DTE or DCE in the Interface Type field.
DTE is the usual operating mode when the device is connected to a Frame Relay switch.
9. Click On or Off in the Active Status Monitor field.
Sets the monitoring of the connection-active status in the LMI status message.
10. (Optional) Click the Advanced Frame Relay Options link to go to the Frame Relay
Advanced Options page.
The Frame Relay Advanced Options page allows you to configure frame relay protocol and
LMI parameters for this device.
Note
The values you enter depend on the settings of the frame relay switch to which you are
connected or to the subscription that your service provider provides.
11. From the Frame Relay Advanced Options page, click Up to return to the Physical Interface
page.
12. Enter the DLCI number in the Create a new interface DLCI text box.
Click Apply.
A new logical interface appears in the Interface column. The DLCI number appears as the
channel number in the logical interface name. The new interface is on by default.
13. (Optional) Enter another DLCI number in the DLCI text box to configure another frame
relay PVC.