Nokia IPSO 4.0 Cell Phone User Manual


 
Nokia Network Voyager for IPSO 4.0 Reference Guide 113
Note
This value must be identical to the keepalive value configured on the system at the other
end of a point-to-point link, or the link state fluctuates.
4. Click Save to make your changes permanent.
To change the keepalive maximum failures in PPP
1. Click Interfaces under Configuration > Interface Configuration in the tree view.
2. Click the physical interface link to configure in the Physical column. Example:
ser-s2p1.
3. Enter a number in the Keepalive maximum failures text box of the Physical Configuration
table to configure the PPP keepalive maximum failures.
Click Apply.
This value sets the number of times the remote system may fail to send a keepalive protocol
message within the keepalive interval before this IP security platform considers the link
down.
4. Click Save to make your changes permanent.
To change the IP address in PPP
Note
Do not change the IP address you use in your browser to access Network Voyager. If you
do, you can no longer access the IP security platform with your browser.
1. Click Interfaces under Configuration > Interface Configuration in the tree view.
2. Click the logical interface link for which to change the IP address in the Logical column.
Example:
ser-s2p1c0.
3. Delete the address from the Local address text box and from the Remote address text box.
Click Apply.
This deletes the old IP address pair.
4. Enter the IP address of the local end of the connection in the Local address text box and the
IP address of the remote end of the connection in the Remote address text box.
Click Apply.
This adds the new IP address pair.
5. Click Save to make your changes permanent.