IPoA Example
This section describes how you might configure the interfaces of your IP security platform in an
example network, using Network Voyager.
The following figure shows the network configuration for this example.
A company has five Ethernet networks in three separate locations. The networks are connected
to each other with three routers that belong to the same logical IP subnet over ATM. This
example configures the ATM interface on Nokia Platform A. The interface is connected to Nokia
Platform B through ATM PVC 42 and to Nokia Platform C through ATM PNC 53. Nokia
Platform B and Nokia Platform C are connected to each other through an ATM PVC; their ATM
interfaces have already configured.
To configure the ATM interface on Nokia Platform A
1. Click Interfaces under Configuration > Interface Configuration in the tree view.
2. Click the physical interface link to configure in the Physical column. Example:
atm-s2p1.
The Physical Interface page appears.
3. Create a logical interface in the Create a new LLC/SNokia Platform RFC1483 interface
section by selecting LIS in the Type list box.
4. Enter
42,53 in the VCI(s) text box.
5. Click Apply.
6. Click the newly created interface (atm-s2p1c0) in the Logical Interfaces table to reach the
Logical Interface page.
7. Enter
10.0.0.1 in the IP Address text box.
8. Enter
24 in the Mask Length text box.
ATM
Switch
00125
eth-s1p1c0
eth-s1p1c0 eth-s2p2c0 eth-s1p1c0 eth-s2p2c0
atm-s2p1c0 (10.0.0.1/24)
PVC 42 to Nokia Platform B
PVC 53 to Nokia Platform C
atm-s3p1c0 (10.0.0.3/24)atm-s3p1c0 (10.0.0.2/24)
Nokia Platform A
Nokia Platform CNokia Platform B